model | XHD-80ML | XHD-100ML | XHD-150ML | XHD-225ML | XHD-408ML | XHD-800ML |
---|
Working size | 400*500*400mm | 500*400*500mm | 500*600*500mm | 500*600*7500mm | 700*800*800mm | 800*1000*1000mm |
Outer box size | 850*1100*1450mm | 950*1100*1450mm | 1100*1200*1700mm | 1150*1200*1700mm | 1200*1400*1900mm | 1300*1600*2100mm |
power | 4.5 KW | 5 KW) | 6 KW | 8 KW | 9 KW | 10 KW |
Temperature range | A:-20℃~150℃ B:-40℃~150℃ C:-60℃~150℃ D:-70℃~150℃ |
Humidity range | 20%~98%R.H |
Average heating rate | The heating rate is adjustable, the slowest heating rate is 3℃/min (no load). |
Average cooling rate | The cooling rate is adjustable, the slowest cooling rate is 5℃/min (no load), or the cooling rate specified by the customer |
Temperature fluctuation | ±1℃ |
Temperature uniformity | ±2℃ |
Humidity deviation | 3%R.H |
Heating rate | 1.0~3.0℃/min |
Cooling rate | 0.7~1.0℃/min |
Controller | Microcomputer digital display controller/GDJS imported programmable touch controller |
Accuracy range | Setting accuracy: temperature ±0.1℃, humidity ±1%R.H, indication accuracy: temperature ±0.1℃, humidity ±1%R.H |
Temperature and humidity sensor | Platinum resistor PT100Ω |
Heating system | Fully independent system, nickel-chromium alloy electric heating heater |
Humidification system | All stainless steel shallow surface evaporative humidifier |
Dehumidification system | Adopt evaporator coil dew point temperature laminar contact dehumidification method |
Water supply system | The humidification water supply is automatically controlled and the surplus water can be recycled to save water and reduce consumption. |
Refrigeration system | French original "Taikang" fully enclosed air-cooled single-stage/cascade compressor refrigeration method |
Circulatory system | Heat-resistant and low-noise air-conditioning motor. Multi-blade centrifugal impeller |
Outer box material | High quality carbon steel plate. Phosphate electrostatic spray treatment |
Inner box material | SUS304 stainless steel plate |
Insulation material | Polyurethane rigid foam |
Door frame insulation | Double-layer high and low temperature resistant aging silicone rubber door sealing strip |
Test hole | 2 sets of sample racks, 1 test lead hole |
Security protection | Leakage, short circuit, over-temperature, water shortage, motor overheating, compressor overpressure, overload, over-current protection/controller power failure memory |
Supply voltage | AC220V±10% 50±0.5Hz three-phase four-wire, or specified by each country |
Operating ambient temperature | 5℃~+30℃ ≤85%R.H |
Non-standard high and low temperature humidity test chambers can be customized according to the specific requirements of users |